ȸ¿ø°¡ÀÔ | ·Î±×ÀÎ | Àå¹Ù±¸´Ï | °í°´¼¾ÅÍ   
 
         
    APCÃâ·ÂÄܼ¾Æ®    
         
    APC [BACK-UPS]    
         
    APC [SMART-UPS]    
         
    APC [SMART RT]    
         
    APC·ÎÄÉÆ®¹èÅ͸®Á¤Ç°    
         
    PCM [BNT]    
         
    PCM [KIN]    
         
    PCM [SMK]    
         
    PCM´º¸Æ½º¹èÅ͸®Á¤Ç°    
         
    UPS[MGE]    
         
    UPS[¸®¹öÆ®]    
         
    19" ·¢ [AVR,UPS]    
         
    ¼öÃâ¿ë [AVR,UPS]    
         
    UPS [¹«Á¤ÀüÀü¿øÀåÄ¡]    
         
    Áß´ë¿ë·® UPS ¹èÅ͸®    
         
    AVR [ÀÚµ¿Àü¾ÐÁ¶Á¤±â]    
         
    Á֯ļöº¯È¯±â [Ãâ·Â110/220V,50/60HZ]    
         
    Á֯ļöº¯È¯±â [Ãâ·Â0~300V,45~65HZ]    
         
    Á֯ļöº¯È¯±â [Ãâ·Â0~300V,40~999HZ]    
         
    IVR    
         
    ÀιöÅÍ[DC12/24/48V]    
         
    Æ®·£½º    
         
 
 
Ä¿¹Â´ÏƼ
  
 ÀÚ·á½Ç  
 Áú¹®°ú ´ë´ä  
 
 
ÀüÈ­¹®ÀÇ
 
    TEL:02-2615-8831

  FAX:02-2615-8839

  H.P:017-293-8589
 
  E-mail ¹®ÀÇ
 
 
  **¼Û±Ý°èÁ¹øÈ£**
*¿ì¸®ÀºÇà
1002-631-441902
*±¹¹ÎÀºÇà
364301-04-040129
*¿¹±ÝÁÖ:±¹±¤È£(»ïdzÆÄ¿ö½Ã½ºÅÛ)
 
 
 
UPS[MGE]
UPS[MGE] > MGE-PE1000CR(2U·¢Å¸ÀÔ)/1KVA(700W)
     
  ÀÌÀü»óǰ MGE-PE1000CR(2U·¢Å¸ÀÔ)/1KVA(700W) ´ÙÀ½»óǰ
 
 


     
»óǰ¸í : MGE-PE1000CR(2U·¢Å¸ÀÔ)/1KVA(700W)
Á¦Á¶È¸»ç : ÇÁ¶û½º
ÆÇ¸Å°¡°Ý : 940,000¿ø
¼ö·® :
 
 
 
 
 
 
 
   
SP-BNT500ASP-BK500EISP-BR 500 IPSA500MT/500VA[300W]
90,000¿ø175,000¿ø185,000¿ø°¡°Ý¹®ÀÇ
 
»óǰ »ó¼¼ ¼³¸í
 
 


 
On-Line¹æ½ÄÀÇ ÃÖ¼ÒÀÇ °ø°£À¸·Î server, PBX, ³×Æ®¿öÅ© Àåºñ¸¦ À§ÇÑ ÃÖ´ë Àü·Â º¸È£
 
 
 Pulsar Extreme C UPS´Â On-Line ¹æ½ÄÀÇ UPS·Î º¸´Ù ¾ÈÁ¤ÀûÀÎ Àü¿øÀ» °ø±ÞÇØ¾ß ÇÏ´Â ¼ÒÇüÀÇ ¹Ì¼Ç-Å©¸®Æ¼ÄÃÇÑ Àåºñ¿¡ È¿À²ÀûÀ¸·Î Ȱ¿ëÇÒ ¼ö ÀÖ´Ù. È®Àå ¹èÅ͸®ÀÇ »ç¿ëÀ¸·Î, ÃÖ´ë°¡µ¿½Ã°£À» ÇÊ¿ä·Î ÇÏ´Â ºÐ¾ß¸¦ À§ÇÑ Àü·Âº¸È£ ¿¬Àå¿î¿ëÀ» À§ÇØ °£ÆíÇÏ°Ô Ãß°¡ ¹èÅ͸® ¸ðµâÀ» ³¢¿ö °¡µ¿½Ã°£À» ¿¬ÀåÇÒ ¼ö ÀÖ´Ù.
   
 ¢Æ Pulsar Extreme CÀÇ Æ¯Â¡
   1. On-line double conversion mode
   2. Automatic-Bypass ±â´É
   3. Complete Installation Kit Á¦°ø
  
 

  
 
Pulsar Extreme1000 C1500 C
¢¹ General
Power (pn)1000 VA / 700 W1500 VA / 1050 W
ÀÔ·Â Àü¾Ð Çô¿ë ¹üÀ§120/140/160 ~ 276 volt (Battery Power »ç¿ë ¹«)
Á֯ļö ¹üÀ§50/60 Hz (auto-selection)
Power factor (THDI)>0.95 (<5%)
Sinusoidal Ãâ·Â ¹üÀ§200/208/220/230/240 volts
Harmonic distortion<4% on linear load, <6% on non-linear load
Efficiency87%88%
Crest factor 3:13:1
Short circuit current (A)2929
Overload capacity (online mode110% permanent, 130% 12s, > 130% 1.5s
¢¹ Batteries
Backup time100% pn50% pn100% pn50% pn
standard718614
Pulsar Extreme C + 1 pulsal EXB27602350
Pulsar Extreme C + 2 pulsar EXB48874186
Pulsar Extreme C + 3 pulsar EXB7013278134
Battery ÀÚ°¡ Áø´Ü»ç¿ëÀÚÁ¤ÀÇ Æ¯Á¤ÁÖÀÇ ÁöÁ¤°¡´É
Ư¡¿Âµµº¯È­¿¡ µû¶ó ¹èÅ͸® ÃæÀüÀü¾ÐÀÌ º¯È­ÇÏ¿© ¹èÅ͸® stress¸¦ ÇØ¼ÒÇÔ
¢¹ Communication
USP portYesYes
RS232 portYesYes
ÃæÀü½Ã°£4hrs4hrs4hrs4hrs
Optional cardsSNMP card
Battery ÀÚ°¡ Áø´ÜStatus information card
¢¹ Environment
Acoustic noise<40 dBAl
Operating temperature0 to 40
¢¹ Standards and certifications
PerformanceEN 50091-3/IEC 62040-3
SafetyEN 50091-1, EN 60950 (RD/), IEC 60
EMCEN 50091-2/IEC 62040-2, EN 55022/B, FCC 47 part 15-subpart B - Class A
 IEC 61000-4-2,/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3
Marking and certificationCE, TUV/GS, UL, cUL, C-Tick
dDesign and manufactureISO 9001
¢¹ ºÎÇÇ (HxWxD) ¹× ¹«°Ô (kg)
UPS (electronics + battery, tower235.5x145x400235.5x145x400235.5x145x505
Rack88(2U)x482.6x43088(2U)x482.6x43088(2U)x482.6x493
Electonics module Tower/Rack10/1412/1615/20
Battery module Pulsr EXB T/R 11.5/1715/2121/27.5
CLA module (without batteies)  8.5/11.5
¢¹ Warranty
 
(1) values for operation at 50%, 66% and 100% rated output
 
Catalog numbersExtreme 1000 CExtreme 155 C
FormatTowerRackTowerRack
UPS66346663526634766353
Warranty + for UPS66818668186681833818
Pulsar EXB66349663556635066356
Warranty + for Pulsar EXB66813668136691366813
Pulsar Extreme 1500 transformer  66357 
Pulsar Extreme 1500 CLA  6635966358

 
 
¢Æ On-line double conversion µðÀÚÀÎ
 Double Conversion On-line µðÀÚÀÎÀº ±³·ùÀü¿øÀ» Á÷·ùÀü¿øÀ¸·Î º¯°æÇÏ¿© ÃàÀüÁö¸¦ ÃæÀü½Ã۰í ÀιöÅ͸¦ ÅëÇØ Á÷·ùÀü¿øÀ» ±³·ùÀü¿øÀ¸·Î º¯°æÇÏ¿© °ø±ÞÇÔÀ¸·Î½á º¸´Ù Á¤ÇöÆÄ¿¡ °¡±õ°Ô ÇÏ¿© ¿ª·ü°ú °íÁ¶ÆÄ¸¦ °³¼±ÇÏ´Â È¿°ú¸¦ Á¦°øÇÑ´Ù.
  
¢Æ Automatic Bypass ±â´É
 °úºÎÇϳª UPS ¿À·ù°¡ ¹ß»ýÇßÀ» ¶§ Pulsar Extreme C ¸ðµ¨Àº ÀÚµ¿À¸·Î Àü¿øÀ» Bypass ½ÃŲ´Ù.
  
¢Æ °íÈ¿À² Battery Charger
 Pulsar Extreme C ¸ðµ¨ÀÇ Battery Charger´Â 2½Ã°£¿¡ 80%±îÁö Backup timeÀ» È®º¸ÇÏ´Â ºü¸¥ ¹èÅ͸® ÃæÀü½Ã°£°ú ¹èÅ͸®ÀÇ ¼ö¸íÀ» ´ÃÀδÙ.
  
¢Æ È®Àå BATTERY MODULE (EXB)
 
Pulsar Extreme C UPS¿¡´Â Ãâ·Â Æ÷Æ® ±×·ì ´ç Power Management Software·Î µ¶¸³ÀûÀ¸·Î ÄÜÆ®·ÑÀÌ °¡´ÉÇϰí Load Segments ±â´ÉÀº ÁÖ¿äÇÑ Àåºñ¿¡ ´ëÇÑ ¹èÅ͸® ¹é¾÷ ½Ã°£À» ´ÃÀδÙ.
  
¢Æ Load-Segment ±â´É
 
Pulsar Extreme C UPS¿¡´Â Ãâ·Â Æ÷Æ® ±×·ì ´ç Power Management Software·Î µ¶¸³ÀûÀ¸·Î ÄÜÆ®·ÑÀÌ °¡´ÉÇϰí Load Segments ±â´ÉÀº ÁÖ¿äÇÑ Àåºñ¿¡ ´ëÇÑ ¹èÅ͸® ¹é¾÷ ½Ã°£À» ´ÃÀδÙ.
 
  
¢Æ Local ¹× Remote ¸ð´ÏÅ͸µ Áö¿ø
 
Pulsar Extreme C´Â Åë½ÅÆ÷Æ®³ª SNMP CARD¸¦ ÅëÇØ Ãâ·ÂÆ÷Æ® ±×·ì ´ç Power Management Software·Î Local À̳ª Remote Áö¿ª¿¡¼­ µ¶¸³Àû ÄÜÆ®·Ñ ¹× ¸ð´ÏÅ͸µÀÌ °¡´ÉÇÏ´Ù.
  
¢Æ Hot-swap »ç¿ëÀÚ ±³Ã¼ °¡´É ¹èÅ͸®
 
¹èÅ͸® ±³Ã¼ °æ°í ±â´ÉÀ» ÅëÇØ ½Ã½ºÅÛ °¡µ¿½Ã°£ÀÇ °¨¼Ò¸¦ ¿¹¹æÇÒ ¼ö ÀÖÀ¸¸ç »ç¿ëÀÚ ¹èÅ͸® ±³Ã¼°¡ °¡´ÉÇÏ´Ù.
¢Æ Side feature

 
 
BACKUP TIME CHART  ´ÜÀ§:ºÐ
VA70070070070010001000100010001500150015001500
OptionalSTD+1EXB+2EXB+3EXBSTD+1EXB+2EXB+3EXBSTD+1EXB+2EXB+3EXB
200331102003005521536050060250429680
300155591137289117524838149238300
50011356491197011516525108184270
6007.52745651349891151995168201
7005.5234153113868911583130175
900    8305070115990137
1000    6264664105285115
1200        8326082
1350        6.5285370
1500        5.5244262


 
Tower/Rack °â¿ëÀ¸·Î »ç¿ë °¡´ÉÇÑ ¼ÒÇü On-line double conversion UPSs
 
 
 Pulsar Extreme C UPS´Â On-line ¹æ½ÄÀÇ UPS·Î º¸´Ù ¾ÈÁ¤ÀûÀÎ Àü¿øÀ» °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù.
Module½Ä È®Àå¹èÅ͸® Ãß°¡±â´ÉÀ¸·Î º¸´Ù ´õ ±ä Back-up TimeÀ» Á¦°øÇÒ ¼ö ÀÖÀ¸¸ç ÀÚü Auto Bypass°¡ ³»ÀåµÇ¾î ÀÖ¾î º¸´Ù ¾ÈÁ¤ÀûÀÎ ¾çÁúÀÇ Àü¿øÀ» °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù.

¢Æ Pulsar Extreme CÀÇ Æ¯Â¡
  1. On-line Double Conversion ¹æ½Ä
  2. Auto-Bypass ³»Àå
  3. Rack/Tower °â¿ë
  4. Battery Hot-Swap

  
 
 1000C1500C2200C3200C
¢¹ Performances
Power rating1000VA/700W1500VA/1050W2200VA/1540W3200VA/2080W
TechnologyOn-Line double conversion (automatic by-pass ³»Àå)
Input voltage window120/140/160 V* to 276 V120/140/160 V* to 284 V
Input frequency50/60 Hz, auto-select, input frequency 40-70 Hz, frequency converter
Output Voltage / Frequency230V, adjustable to 200/208/220/230/240 V, 50/60 Hz +/-0,5 %
Overload capacity110% : continuous, 130% : 12 s then on by-pass, >130% : 1.5 s then on by-pass
Battery testAutomatic battery test once a week (adjustable through UPS-Driver software supplied)
Battery managementEXB auto recognition, automatic runtime adjustment,Start Up protection against deep discharge
¢¹ Typical runtime at 50% / 70% of rated power
Pulsar EXtreme C18 mn / 11 mn 14 mn / 10 mn 17 mn / 12 mn 15 mn / 10 mn
Pulsar EXtreme C + 1 EXB60mn / 40mn 80 mn / 50 mn 85 mn / 60mn 60 mn / 40mn
Pulsar EXtreme C + 4 EXB170 mn / 110 mn 210 mn / 135 mn 285 mn / 200mn 190 mn / 130 mn
¢¹ Input / output connection
InputIEC C14 (10A)IEC C20 (16A)
Output6 IEC C13 (10A)1 IEC C19 (16 A)
4 IEC C13 (10 A)
Including Powershare outlets2 IEC C13 individually switchable outlets
(remote ON/OFF, load shedding, sequential start-up)
¢¹ Power management
Standard port1 USB port + 1 Serial port
Available slot1slot for SNMP/Web Minislot card (Ref 66244) or status information card (Ref 66246)
Remote Power Offoption with status information card ref 66246Standard
¢¹ Dimensions (H x W x D in mm) / Weight (in kg)
Tower UPS or EXB235,5x145x400235,5x145x505UPS : 86,5 (2U) x 438 (19¡±) x 654,2
Rack UPS or EXB88 (2U)x482,6(19¡±)x43088(2U)x482,6 (19¡±)x493EXB : 87,9 (2U) x 438 (19¡±) x 632
UPS weight Tower / Rack12 kg / 16 kg15 kg / 20kg35 kg36 kg
EXB weight Tower / Rack15 kg / 21kg21 kg / 27.5kg42 kg42 kg
¢¹ Standards
ApprovalsCE / TuV-GS Mark / CB Report / UL 1778, cUL
Performance and safetyIEC/EN 62040-1-1, EN 60 950-1 (RD), IEC/EN 62 040-3
EMCEN 50091-2, IEC 62040-2 class B (even with EXB battery extensions)

 
 
¢Æ Rack & Tower °â¿ë
 Pulsar Extreme C UPS´Â Rack/Tower °â¿ëÀ¸·Î »ç¿ëÇÒ ¼ö À־ »ç¿ëÀÚ È¯°æ¿¡ µû¶ó ´Ù¾çÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Rack °¡À̵å ŶÀÌ ³»ÀåµÇ¾î À־ À¯µ¿ÀûÀ¸·Î ¼³Ä¡°¡ °¡´ÉÇϰí 2UÀÇ Å©±â·Î ·¢°ø°£À» Àý¾àÇÒ ¼ö ÀÖ½À´Ï´Ù.
   
 
  
¢Æ Module½Ä È®Àå Battery
 Pulsar Extreme C UPS´Â Áß¿äÇÑ ºÎÇÏÀÇ Back-Up TimeÀ» »ç¿ëÀÚÀÇ ¿ä±¸¿¡ µû¶ó È®Àå °¡´ÉÇÕ´Ï´Ù. º°µµÀÇ Charger¾øÀÌ 1~4°³ÀÇ Battery°¡ È®Àå °¡´ÉÇÕ´Ï´Ù. 2200 + 4 EXB : 3½Ã°£ 20ºÐ (70% Load½Ã) 3200 + 4 EXB : 2½Ã°£ 10ºÐ (70% Load½Ã)
   
 
  
¢Æ RPO (Remote Power OFF)
 
 Dry ContactÀ» ÀÌ¿ëÇØ¼­ ¿ø°Ý¿¡¼­ UPS Ãâ·ÂÀ» OFF ½Ãų ¼ö ÀÖ½À´Ï´Ù.
  
¢Æ UPS Power Management
 
 SNMP/Web Minislot card 10/100
Environment Sensor for SNMP/Web cards
Status information card (contacts)
  
¢Æ UPS Ãâ·Â Àü¾Ð&Á֯ļö Á¶Á¤
 
 
UPSÀÇ On-Line ¸ðµå»óÅÂ, ÀԷ°ú Ãâ·Â Á֯ļö ÀÏÄ¡ »óÅÂ
UPSÀÇ On-Line ¸ðµå»óÅÂ, Ãâ·Â Á֯ļö 50/60Hz ÀÚµ¿ Á¶Á¤ (+/- 0.5%)
UPSÀÇ Batteryµ¿ÀÛ ¸ðµå »óÅ , Ãâ·Â Á֯ļö 50/60Hz ÀÚµ¿ Á¶Á¤ (+/- 0.5%)
  
¢Æ UPS Bypass ȯ°æ¼³Á¤
 

Bypass ½Ã ÀÔ·ÂÀü¾Ð Çã¿ë ¹üÀ§ (184V ~ 264V)
UPSÀÇ °úºÎÇϽà Bypass ¸ðµå ¼±Åà °¡´É
UPS ÀÔ·Â Àü¾ÐÀÇ ¹üÀ§¸¦ ¹þ¾î³µÀ» ¶§ Bypass ¸ðµå ¼±Åà °¡´É
  
¢Æ Pulsar Extreme 3200C

 
 ¹è¼ÛÀÏ

¹è¼Û¹æ¹ýÀº Åùè ÀÔ´Ï´Ù.

ÁÖ¹®ÇϽг¯·ÎºÎÅÍ 1 ~ 4ÀϾȿ¡ ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.
¿Â¶óÀÎ ÀԱݽà ÀÔ±Ý È®ÀÎ ÈÄ 1 ~ 4ÀÏ
¹è¼Û ¾È³»
 
 
 
 ¹Ýǰ ¾È³»

°í°´ÀÇ º¯½É¿¡ ÀÇÇÑ ±³È¯ ¹× ¹ÝǰÀÎ °æ¿ì¿¡´Â ¹è¼Ûºñ´Â ¼ÒºñÀںδãÀÔ´Ï´Ù.
»óǰÀÇ ÀÌ»ó¿¡ ÀÇÇÑ ±³È¯ ¹× ¹ÝǰÀÎ °æ¿ì¿¡´Â ¹è¼Ûºñ´Â ÆÇ¸ÅÀںδãÀÔ´Ï´Ù.
¹®ÀÇ : 02-2615-8831
¹Ýǰ ¾È³»
 
 
 
 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-17-27507   Åë½ÅÆÇ¸Å¾÷½Å°í¹øÈ£ ±¸·Î±¸Ã» Á¦2764È£
¼­¿ï½Ã ±¸·Î±¸ ±Ãµ¿ 213-21 ¿ì½Åºôµù 1Ãþ  »ïdzÆÄ¿ö½Ã½ºÅÛ  ´ëÇ¥ ±¹±¤È£
°í°´¼¾ÅÍ TEL:02-2615-8831,FAX:02-2615-8839,H.P:017-293-8589 power8831@naver.com
[¾à°ü] [°³ÀÎÁ¤º¸ º¸È£Á¤Ã¥] [°³ÀÎÁ¤º¸ Ã¥ÀÓÀÚ ±¹±¤È£]
Copyright ¨Ï »ïdzÆÄ¿ö½Ã½ºÅÛ All Rights Reserved.