APC [BACK-UPS]
>
SP-BR 1500 I
SP-BR 1500 I
´ÙÀ½»óǰ
»óǰ¸í : SP-BR 1500 I
Á¦Á¶È¸»ç : APC
ÆÇ¸Å°¡°Ý : Àüȹ®ÀÇ
¼ö·® :
BACK-UPS RS 1500I
SP-SUA1000I(670W)
MGE-PE1100/1.1KVA(700W)
SP-SMK1000A(1K)
SP-KIN1000AP(1K)
406,000¿ø
350,000¿ø
380,000¿ø
250,000¿ø
¢ÂÁ¦Ç° °³¿ä
¼³ ¸í : APC Back-UPS RS, 1500VA/865W, ÀÔ·Â 230V/ Ãâ·Â 230V, Interface Port USB, Extended runtime model
ÀϹÝÀûÀΠƯ¡ : °æº¸À½, ÀÚµ¿ ÀÚ°¡ Å×½ºÆ®, ÀÚµ¿ Á¾·á, ÀÚµ¿ Àü¾Ð Á¶Àý(AVR), ¹è¼± °íÀå Ç¥½Ã±â ±¸¼º, Cold-start,
°£´ÜÇÑ °úºÎÇÏ º¹±¸, Hot Swap Batteries, Áö´ÉÇü ¹èÅ͸® °ü¸®,ÀÎÅÍ³Ý FAX - ¸ðµ© - DSL ¼Áö º¸È£, ³«·Ú ¹× ¼Áö
¹æÁö, °úºÎÇÏ Ç¥½Ã±â, PC ¿Í Mac ȣȯ, ¹èÅ͸® ±³Ã¼ Áö½Ãµî, ¸®¼Â°¡´ÉÇÑ È¸·ÎÂ÷´Ü±â, Connection Failure, Æ®·£½º
Æ÷¸Ó ºí·Ï °£°Ý, ¹«ÀÎ ¾ÈÀü Á¾·á, USB ¿¬°á, »ç¿ëÀÚ ±³Ã¼ °¡´É ¹èÅ͸®
³»¿ë¹° : ¼ÒÇÁÆ®¿þ¾î žÀç CD, Cord Management Straps,
¾ÈƼ¹ÙÀÌ·¯½º ¹«·á Æò°¡ÆÇ : ¹æÈº® : email °³ÀÎÁ¤º¸ : ½Ã½ºÅÛ º¹±¸ ¹× ¿Â¶óÀÎ ¹é¾÷ ¼ÒÇÁÆ®¿þ¾î, USB ÄÉÀ̺í,
»ç¿ë ¼³¸í¼
¢ÂÅë½Å°ú °ü¸®
ÀÎÅÍÆäÀ̽º Æ÷Æ® : USB
Á¦¾îÆÇ : On Line : On Battery : Replace Battery and Building Wiring Fault°¡ ÀÖ´Â LED »óÅ µð½ºÇ÷¹ÀÌ
°æº¸À½ : ¹èÅ͸® »ç¿ëÁßÀÏ ¶§ °æº¸ : Àú¹èÅ͸® °æº¸ : Áö¿¬ ±¸¼º°¡´É
Emergency power off :
¢ÂÃâ·Â
Ãâ·Â ¿ë·® : 1,500 VA
Ãâ·Â ¿ë·® : 865 Watts
°øÄª Ãâ·ÂÀü¾Ð : 230 V
Output Voltage Note :
Ãâ·Â ¿¬°á À¯Çü : (6)IEC 320 C13
(2)IEC 320 C13 (Surge)
¢ÂÀÔ·Â
°øÄª ÀÔ·ÂÀü¾Ð : 230 V
ÀÔ·Â Á֯ļö : 47-63
ÀÔ·Â ¿¬°á¹è¼± : IEC-320 C14
Çã¿ë ÀÔ·ÂÀü¾Ð ¹üÀ§ : 175 - 295 V
Çã¿ë ÀÔ·Â Àü¾Ð Á¶Á¤ ¹üÀ§ : 160 - 286 V
¢Â¼Áö ¹æÁö ¹× ÇÊÅ͸µ
¼Áö ¿¡³ÊÁö Á¤°Ý : 180 joules
ÇÊÅ͸µ : Full time multi-pole noise filtering : 5% IEEE surge let-through :
zero clamping response time : meets UL 1449
¢ÂÁ¤Àü º¸»ó ½Ã°£
¹ÝºÎÇÏ¿¡¼ ÀϹÝÀûÀÎ ¹é¾÷½Ã°£ : 12.7 minutes (432.5 Watts)
ÀüºÎÇÏ¿¡¼ ÀϹÝÀûÀÎ ¹é¾÷½Ã°£ : 3.7 minutes (865 Watts)
¢Â¹èÅ͸®
¹èÅ͸® À¯Çü : ¹«º¸¼ö ¹«´©¾× ¿¬ÃàÀüÁö(sealed Lead-Acid battery) : ´©¾×¹æÁö
¢Â¹°¸®Àû
ÃÖ´ë ³ôÀÌ : 14.60 inches ( 37.08 cm)
ÃÖ´ë Æø : 3.40 inches ( 8.64 cm)
ÃÖ´ë ±íÀÌ : 13.10 inches ( 33.27 cm)
¼øÁß·® : 25.50 lbs ( 11.59 kg)
¼±Àû Áß·® : 28.20 lbs ( 12.82 kg)
¼±Àû ³ôÀÌ : 17.90 inches ( 45.47 cm)
¼±Àû Æø : 8.00 inches ( 20.32 cm)
¼±Àû ±íÀÌ : 16.40 inches ( 41.66 cm)
Color : Beige
Unit per Pallet :
UPCÄÚµå : 731304193173
¢Âȯ°æ
ÁÖÀ§ ¿Âµµ(µ¿ÀÛ½Ã) : 0 - 40 ¡ÆC (32 - 104¡ÆF)
»ó´ë ½Àµµ(µ¿ÀÛ½Ã) : 0 - 95%
°í µµ(µ¿ÀÛ½Ã) : 0-10000 feet (0-3000 m)
º¸°ü ¿Âµµ : -5 - 45 ¡ÆC (23 - 113¡ÆF)
º¸°ü »ó´ë½Àµµ : 0 - 95% Non-condensing
º¸°ü °íµµ : 0-50000 feet (0-15000 m)
¹ß¿·® : 180 BTU/hr
¢ÂÀûÇÕ ±Ô°Ý
½ÂÀÎ : A-tick, C-tick, CE, GOST, IRAM, PCBC, VDE
Ç¥ÁØ º¸Áõ : 2³â
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-17-27507 Åë½ÅÆÇ¸Å¾÷½Å°í¹øÈ£ ±¸·Î±¸Ã» Á¦2764È£
¼¿ï½Ã ±¸·Î±¸ ±Ãµ¿ 213-21 ¿ì½Åºôµù 1Ãþ »ïdzÆÄ¿ö½Ã½ºÅÛ ´ëÇ¥ ±¹±¤È£
°í°´¼¾ÅÍ
TEL:02-2615-8831,FAX:02-2615-8839,H.P:017-293-8589
power8831@naver.com
[
¾à°ü
] [
°³ÀÎÁ¤º¸ º¸È£Á¤Ã¥
] [°³ÀÎÁ¤º¸ Ã¥ÀÓÀÚ
±¹±¤È£
]
Copyright ¨Ï
»ïdzÆÄ¿ö½Ã½ºÅÛ
All Rights Reserved.